Overview
Readers will learn how to reset an EdgeSwitch XP (ES-XP) to the factory default settings.
NOTES & REQUIREMENTS:
Applicable to the following EdgeSwitch XP models:
Device used in this article: |
Using the Reset Button
The EdgeSwitch XP can be reset to factory defaults by holding the reset button while the device is running:
To perform a runtime reset, follow the steps below:
1. Plug in the power cable.
2. Wait until the device has fully booted.
3. Press and hold the reset button for around ~10 seconds until the amber (right) LED of the MGMT port starts blinking.
4.The amber (right) LED of the MGMT port will blink 4 times, indicating that the device is being reset.
5. Wait for the reset process to complete, during which the EdgeSwitch XP will automatically reboot.
6 Access the device by navigating to the https://192.168.1.20 address using a Web browser.
Related Articles
EdgeSwitch XP - How to Upgrade the Firmware
EdgeSwitch & EdgeSwitch X - How to Reset to Factory Defaults